Lechler Pneumatic shut-off valve for single nozzle holder – nozzle holder not included in scope of delivery, order as accessory if required.
The advantages:
- Design of the field spray line continuously as a ring line with circulation or return flow
- Keeping the spraying pressure in the spray line with closed nozzles
- Immediate spray buildup of all nozzles after opening the pneumatic closing valves
- Simple boom assembly, no boom section valve required
- Rotatable pneumatic connection piece facilitates assembly and routing of the air pressure line in the boom
Technical data:
- Materials: PA, POM, Viton®, PTFE, stainless steel
- Pressure ranges: Max. 8 bar, air pressure min. 4.5 bar
- Emergency stop function: At air pressure below 4.5 bar
- Valve switching time: 0.2 sec.